Costs
A heat pump instead of a gas boiler: what you gain and what you lose over 15 years
On underfloor heating the heat pump only just beats gas; on radiators at 55 °C gas stays cheaper unless electricity costs under 1.10 lei/kWh. Here are the 15-year numbers and what changes in the house.
With underfloor heating, a heat pump that replaces your gas boiler comes out slightly cheaper on the bill, but only just: at 1.35 lei/kWh for electricity you save about 260 lei a year on a 150 m² house. On radiators that need 55 °C, gas stays cheaper unless you pay less than about 1.10 lei for electricity. The heat pump pays off in other situations, which we go through below with every figure shown.
We use the same prices and efficiencies as in the article on what a winter with a heat pump costs and as the calculator on our sizing page, checked on 17.09.2026. Nothing has been nudged in the heat pump's favour. Where gas comes out ahead, we say so.
Gas boiler or heat pump: what a kWh of heat costs
To compare two systems fairly, look at the price of one kWh of heat delivered into the house, not the price of the fuel. Gas costs 280.38 lei/MWh including VAT (Distrigaz Sud, final prices from 01.07.2026), which is 0.28 lei/kWh. A condensing boiler has a seasonal efficiency of 92%, so one kWh of heat costs 0.28 ÷ 0.92 = 0.304 lei.
For the heat pump, the electricity price is divided by the SCOP, its average efficiency over the season. We use the Heat Pump KEYMARK certified SCOP of the Chofu R290 10 kW Premium: 4.68 at 35 °C, the underfloor regime, and 3.61 at 55 °C, the radiator regime. The electricity prices are the three offers in our calculator, all including VAT: 1.11 lei (Hidroelectrica Viitor Hidro, Muntenia), 1.35 lei (PPC Fix Online) and 1.69 lei (PPC Simplu Online).
| System | Electricity at 1.11 lei | Electricity at 1.35 lei | Electricity at 1.69 lei |
|---|---|---|---|
| Heat pump, underfloor (SCOP 4.68) | 0.237 lei | 0.288 lei | 0.361 lei |
| Heat pump, radiators at 55 °C (SCOP 3.61) | 0.307 lei | 0.374 lei | 0.468 lei |
| Condensing gas boiler (92%) | 0.304 lei, whatever the electricity offer | ||
| New beech log boiler (75%) | 0.248 lei | ||
| Pellet boiler (75%) | 0.628 lei | ||
The break-even point is easy to work out. The heat pump matches gas when the electricity price equals 0.304 × SCOP: 1.42 lei/kWh on underfloor heating and 1.10 lei/kWh on radiators at 55 °C. Below those prices the heat pump wins; above them, gas does. It works the other way round too: at 1.35 lei electricity, the heat pump on radiators breaks even if gas rises to 0.344 lei/kWh, about 23% above today's price.
The gas price is capped by Emergency Ordinance 12/2026, which applies from 1 April 2026 to 31 March 2027 and has no written follow-up. The 1.11 lei electricity offer runs until 30.09.2026. Over 15 years both will change. The tables below keep today's prices constant, because any other assumption would be guesswork.
What you gain and what you lose over 15 years
The worked example: a 150 m² two-storey house, well insulated (55 W/m²), in climate zone II (Oradea, Arad, Bucharest). It needs 8.25 kW and, over a year, 8.25 × 1,980 hours = 16,335 kWh of heat for space heating alone. The hours come from Eurostat heating degree days for Romania, 2021–2025 average. The right heat pump is 8 kW, for example the Chofu 8 kW Standard.
| System and electricity price | Per year | Over 15 years | Compared with gas, over 15 years |
|---|---|---|---|
| Gas boiler | 4,972 lei | 74,580 lei | reference |
| Heat pump, underfloor, 1.11 lei | 3,874 lei | 58,110 lei | 16,470 lei less |
| Heat pump, underfloor, 1.35 lei | 4,712 lei | 70,680 lei | 3,900 lei less |
| Heat pump, underfloor, 1.69 lei | 5,899 lei | 88,485 lei | 13,905 lei more |
| Heat pump, radiators 55 °C, 1.11 lei | 5,023 lei | 75,345 lei | 765 lei more |
| Heat pump, radiators 55 °C, 1.35 lei | 6,109 lei | 91,635 lei | 17,055 lei more |
| Heat pump, radiators 55 °C, 1.69 lei | 7,647 lei | 114,705 lei | 40,125 lei more |
Here is where one row comes from: 16,335 kWh of heat ÷ 4.68 = 3,490 kWh of electricity; × 1.35 lei = 4,712 lei a year; × 15 = 70,680 lei. For gas: 16,335 ÷ 0.92 = 17,755 kWh of gas; × 0.28 lei = 4,972 lei a year.
The table shows something few sellers mention: your electricity contract matters more than the appliance. The same heat pump on the same underfloor heating can save 16,000 lei over 15 years or lose 14,000, depending on the tariff alone. Check what you actually pay on your bill and compare offers on the ANRE comparison tool before you decide anything.
The investment: how to work out the payback
If your boiler works fine, you compare it, at zero further cost, with an installed heat pump. If the boiler has to be replaced anyway, you compare the heat pump with a new boiler: a 24 kW condensing boiler costs 4,098 lei including VAT, appliance only (Ariston Clas One 24, dedeman.ro, 17.09.2026). Each heat pump's price is on its own page in the catalogue, and we price installation on site, as separate line items.
The formula is simple: difference in investment ÷ yearly saving = years to pay back. With a 260 lei yearly saving (underfloor, electricity at 1.35), the heat pump does not pay for itself from the bill within 15 years against a new boiler. With 1,098 lei a year (electricity at 1.11), you put aside 16,470 lei over 15 years. On radiators at 55 °C it does not pay back at today's prices. Put plainly: if your only criterion is the winter bill and you have gas, the pure financial case does not push you towards a heat pump.
What the table leaves out
- Domestic hot water. It is added to both systems, so it does not change the ranking.
- Servicing. A gas installation needs a mandatory technical check at least every 2 years and an overhaul at least every 10 years (ANRE Order 179/2015, art. 3). The heat pump needs a yearly service, required for the 3-year unit and 5-year compressor warranty (details). We have not put these in lei, because prices vary from firm to firm.
- Cooling. An air-to-water heat pump can cool in summer through the same system, if the emitters allow it. A boiler cannot.
- Sunshine and heat from inside the house. The degree-day method does not subtract them, so every figure is an upper bound, equally for gas and for the heat pump.
When the heat pump pays off and when gas stays cheaper
The heat pump is worth it, in order of how strong the argument is:
- You have no gas at the gate. Against pellets or direct electric heating, the heat pump wins by a wide margin: 0.29 lei against 0.63 lei and 1.35 lei per kWh of heat.
- You have underfloor heating and an electricity contract below 1.42 lei/kWh. See also heat pumps with underfloor heating.
- You have, or want, solar panels. Summer generation does not heat the house in winter, but it cuts the rest of the bill; we have written separately about heat pumps and solar panels.
- You want cooling in summer and no longer want gas burning in the house, a chimney and gas inspections.
Gas stays cheaper on the bill if your radiators really need 55 °C all winter and you pay more than 1.10 lei/kWh for electricity. Insulation does not change who wins per kWh, but it multiplies the difference: a poorly insulated house needs almost twice as much heat, so the loss on radiators doubles as well, and the heat pump has to be bigger. If you are planning to insulate, do it before the heat pump.
Keep the boiler? The hybrid option
You do not have to choose one or the other. Chofu heat pumps have a controller function the manual calls EHS (external heat source), designed for a boiler kept alongside the heat pump. The installation manual describes two modes:
- Replacement: below an outdoor temperature you set (default −5 °C, adjustable from −20 to +20 °C), the compressor stops and the boiler takes over the heating. The boiler also starts if the heat pump stops because of a faulty sensor.
- Supplementary: the boiler only comes in when the heat pump cannot bring the water to the required temperature on its own.
The manual's condition: the boiler is connected through a buffer tank, and the function covers space heating only, not the hot water cylinder. With the table above in mind, a hybrid makes sense with small radiators, where on the coldest days the heat pump would have to push the flow temperature high, exactly where its efficiency is weakest.
Often you do not need it. The R290 range heats water up to 75 °C and runs down to −20 °C outside, so it works alone on standard radiators without a backup heater. Larger buildings do not need gas either: at Hanul Pescarilor in Oradea, three heat pumps in cascade replaced two gas boilers. And a boiler you keep is not free: the 2-year check, the 10-year overhaul and chimney cleaning remain mandatory as long as the gas installation is in use.
What changes in the house
Radiators
They do not necessarily change. What matters is how large they are compared with each room's heat demand, because that sets the flow temperature and therefore the bill. Radiators larger than needed, as most are in houses insulated after they were built, run with water well below 55 °C for much of the winter. The room-by-room check, using the EN 442 formula, is in the article heat pumps with old radiators.
The hot water cylinder
If you have a combi boiler with instant hot water, you have no cylinder at all, and the heat pump needs one. If you have a cylinder made for a boiler, its coil is usually too small: the heat pump sends water at 50–55 °C, not 70–80 °C, and needs a coil of 3–4 m². Which volume to choose and why is in the article on hot water cylinders.
The electrical connection
The heat pump runs on electricity and draws several kilowatts from the grid: the 8 kW Standard model reaches 16.6 A per phase at maximum current, and a single-phase 16 kW model 25.3 A. Under ANRE Order 102/2015, a single-phase connection is normally granted for up to 11 kVA. Check the approved power on your connection certificate before asking for a quote; the details are in the article on single-phase or three-phase.
Where the outdoor unit goes
A boiler sits in the kitchen or a boiler room. An air-to-water heat pump has an outdoor monobloc unit, connected to the house only by water pipes, with no refrigerant connections made on site. Distance to the neighbours and to bedroom windows matters; we cover it in noise and placement.
What to do with the gas connection and the chimney
You are not obliged to give up gas. If you keep the gas hob or the boiler as a backup, the installation remains yours, with its obligations: under ANRE Order 179/2015, the end customer is responsible for maintaining the installation, the technical check is due at least every 2 years, and at the check you show proof that the chimney has been cleaned and inspected and that the gas appliances have had their periodic inspection.
If you stop using gas altogether, you can ask for disconnection through your supplier. If you want to come back later, you send the supplier a reconnection request, possibly sign a new contract, pay the reconnection fee, and the network operator reconnects you within 24 hours at most (Distrigaz Vest, FAQ, checked on 27.09.2026). One detail to watch: if the installation stays unused for more than 6 months, a technical overhaul is mandatory before it is used again (ANRE Order 179/2015, art. 3(3)).
A heat pump burns nothing, so it needs no chimney. The existing chimney can stay; what you do with it afterwards has nothing to do with the heat pump. Removing the gas service connection entirely is a matter for the distribution operator in your area, and we have not found its conditions and costs published in a form we can cite.
Switching from gas to a heat pump, step by step
- Find out the house's heat demand in kW. The sizing calculator gives you a ballpark figure; we do the full calculation before the quote.
- Check the radiators room by room and decide whether they work as they are, whether you change one or two, or whether you keep the boiler in hybrid mode.
- Look at your electricity connection certificate: what power is approved and whether you have one phase or three.
- Choose a cylinder with an enlarged coil and, where needed, a buffer tank.
- Ask for an itemised quote: heat pump, cylinder, installation, transport. Changes to the indoor heating system and building work are usually not part of the installation and are listed separately.
- Installation takes one day in a house where the distribution pipework is already in place, and two days with a cylinder and new pipe runs. At the end the installer sets the heating curve and shows you the controller (what installation includes).
- Only after the first winter do you decide what to do with gas: keep it as a backup, keep just the hob, or ask for disconnection.
One thing to know if you are considering the R32 models: from 1 January 2027, new monobloc heat pumps using refrigerants with a GWP of 150 or more can no longer be placed on the EU market (Regulation (EU) 2024/573). Units already installed remain legal and can be serviced. The difference between the two ranges is explained in R290 or R32.
Frequently asked questions
What is a heat pump "boiler"?
Many people call an air-to-water heat pump that: it does the same job as a boiler, heating the water in the radiators or underfloor pipes and in the cylinder, but it takes the heat from the outside air instead of burning gas. It connects to the same system in the house.
Air-to-water heat pump or gas boiler: which is cheaper?
On underfloor heating, the heat pump, if you pay less than 1.42 lei/kWh for electricity; at 1.35 lei the difference is small, about 260 lei a year for 150 m². On radiators at 55 °C, gas, unless your electricity costs less than 1.10 lei/kWh.
What are the disadvantages of an air-to-water heat pump compared with gas?
The investment is higher, the bill rises if electricity gets more expensive, you need space outside for the unit and, often, a new cylinder. On radiators that need very hot water, the yearly cost comes out above gas with most electricity offers.
Can I keep the gas boiler as a backup?
Yes. The Chofu controller can start the boiler below an outdoor temperature you choose, or when the heat pump cannot keep up, with the connection made through a buffer tank. The gas installation keeps its 2-year check and 10-year overhaul.
What happens to my gas contract if I no longer use it?
You can ask for disconnection through your supplier. Reconnection later is done on request, for a fee, within 24 hours at most, but after more than 6 months unused the installation needs a technical overhaul before it is started again.
Work it out for your house
On the sizing page you enter floor area, insulation, windows and heating type, and the result shows the right output and the yearly cost compared with gas, at your own tariff. If you would rather have a quote with installation straight away, send us your house details and we will tell you honestly whether gas comes out cheaper in your case.
Next step
Find the heat pump that fits
Same questions, two minutes, no contact details.
Next steps
If you're clear on the output
Your next step depends on where you've got to: the figure for your house, the models that cover it, or who does the installation.