Heat pump sizing Calculator: how many kW you need and what your heating costs compared with gas, electricity, pellets or firewood
An undersized heat pump runs non-stop and still does not heat the house. An oversized one starts and stops often, uses more electricity and wears out faster. The calculator below asks the same questions the technician asks on site: floor area, insulation, windows, heating system and hot water. You get the power in kW, the right Chofu model and what your heating costs per year compared with gas, pellets, firewood or direct electric heating.
Tell us about your house
These are the questions the technician asks on site. The answer updates as you fill them in.
House
Heating system
Insulation
What's included besides the heat pump
- Hydraulic connection kit (valves, magnetic filter, anti-vibration flexible hoses)
- Expansion vessel for the heating circuit
- Chofu CMR-2613 controller with room thermostat
- Heat pump boiler 200 liters SILO-200-1W-G
The “from” amount only covers items that already have a price; we set the rest in the quote. This is an estimate, not a final price. Installation and delivery are not included: an authorised Chofu partner installer does the installation, and we set the delivery in the quote, based on your address. Final price after survey and quote.
Request a full quoteRequest received
We'll send you the full quote, with the final price, within one working day. If needed, we'll call you first to arrange a survey.
What your heating costs you per year
For a 140 m² house, well insulated, 8.5 kW, underfloor heating.
What do you pay for electricity?
| System | Per year | Per month | Compared with Chofu |
|---|---|---|---|
| Wood-fired boiler | 3,781 lei | 315 lei | −617 lei |
| NIBE S2125-8 | 4,116 lei | 343 lei | −281 lei |
| Bosch Compress 3400i AWS | 4,361 lei | 363 lei | −37 lei |
| Chofu heat pump | 4,398 lei | 366 lei | – |
| Daikin Altherma 3 M, 8 kW | 4,465 lei | 372 lei | +67 lei |
| Condensing gas boiler | 4,640 lei | 387 lei | +242 lei |
| Panasonic Aquarea L, 9 kW | 4,775 lei | 398 lei | +378 lei |
| Pellet boiler | 9,574 lei | 798 lei | +5,177 lei |
| Direct electric heating | 20,582 lei | 1,715 lei | +16,184 lei |
| IDM AERO SLM | SCOP not published at 35 and 55 °C | ||
Send the sizing to NEDAVI
We check the figure with a technician, then you get an itemised quote: heat pump, cylinder, installation, delivery. No obligation.
How many kW you need: table by floor area and insulation
The table uses the same formula as the calculator above: 55 W/m² for a well insulated house, 75 W/m² for average insulation and 100 W/m² for a poorly insulated one, multiplied by the heated floor area, corrected for the ceiling height (2.6 m) and the shape of the house (ground floor plus first floor), plus 0.8 kW for the hot water of 4 people. The proposed model is for underfloor heating.
| Heated floor area | well insulated (55 W/m²) | average insulation (75 W/m²) | poorly insulated (100 W/m²) |
|---|---|---|---|
| 80 m² |
5.2 kW Chofu 6 kW R32 |
6.8 kW Chofu 8 kW R290 Standard |
8.8 kW Chofu 8 kW R290 Standard |
| 100 m² |
6.3 kW Chofu 6 kW R32 |
8.3 kW Chofu 8 kW R290 Standard |
10.8 kW Chofu 10 kW R32 |
| 120 m² |
7.4 kW Chofu 8 kW R290 Standard |
9.8 kW Chofu 10 kW R32 |
12.8 kW Chofu 12 kW R32 |
| 150 m² |
9.1 kW Chofu 10 kW R32 |
12.1 kW Chofu 12 kW R32 |
15.8 kW Chofu 16 kW R32 |
| 180 m² |
10.7 kW Chofu 10 kW R32 |
14.3 kW Chofu 16 kW R32 |
18.8 kW Chofu 16 kW R32 · below demand, ask for a survey |
| 200 m² |
11.8 kW Chofu 12 kW R32 |
15.8 kW Chofu 16 kW R32 |
20.8 kW Chofu 16 kW R32 · below demand, ask for a survey |
| 250 m² |
14.6 kW Chofu 16 kW R32 |
19.6 kW Chofu 16 kW R32 · below demand, ask for a survey |
25.8 kW Chofu 16 kW R32 · below demand, ask for a survey |
| 300 m² |
17.3 kW Chofu 16 kW R32 |
23.3 kW Chofu 16 kW R32 · below demand, ask for a survey |
30.8 kW Chofu 16 kW R32 · below demand, ask for a survey |
A model is proposed if its power covers at least the demand minus 10%, because the design day only comes round a few times each winter, and it is flagged as oversized from 35% above the demand. For radiators or a mixed system, only the models that take the flow temperature to 75 °C qualify, that is the R290 range; the calculator above allows for this when you choose "Radiators" or "Mixed".
Climate zone and design outdoor temperature
The power is sized for the design outdoor temperature of your zone (SR 1907-1), not for the winter average. The yearly cost in the panel above uses 1,980 equivalent hours of running at nominal power, the figure for zone II, and the Chofu SCOP of 4.68 at a 35 °C flow temperature (underfloor heating) or 3.61 at 55 °C (radiators).
| Zone | Design temperature | Equivalent hours per year | Towns |
|---|---|---|---|
| I | −12 °C | 2,175 h | Constanța |
| II | −15 °C | 1,977 h | Oradea, Arad, București |
| III | −18 °C | 1,813 h | Cluj, Sibiu, Iași |
| IV | −21 °C | – | – |
| V | −25 °C | – | – |
How the configurator works out the heat pump power
The power of a heat pump is chosen from how much heat the house loses on the coldest design day, not from the square metres on their own. Two 150 m² houses can need 9 kW or 16 kW, depending on the insulation, the ceiling height and how many people use hot water. The formula behind the calculator is simple and you can check it with a pencil:
kW = heated floor area × W/m² ÷ 1000 × (ceiling height ÷ 2.6 m) × storey factor + people × 0.2 kW
The W/m² value comes from the insulation: 55 W/m² for a well insulated house, 75 W/m² for average insulation and 100 W/m² for a poorly insulated house. We work out the insulation grade from three answers, with different weights: the external walls count for 50% (good from 10 cm of polystyrene or equivalent, average from 5 cm), the loft or roof for 30% (good from 15 cm, average from 8 cm) and the windows for 20% (triple glazing, double glazing or old frames). Mineral wool, rock wool or XPS are converted into equivalent centimetres of polystyrene, so the comparison is fair.
The storey factor is 1.10 for a single storey house, which loses heat through both the floor and the roof over the same area, 1.00 for a ground floor plus first floor and 0.95 when the attic is lived in. A 3 m ceiling instead of 2.6 m adds 15% to the demand, because you are heating more air.
An example: a 150 m² house on two storeys, 2.6 m ceilings, average insulation, four people. 150 × 75 ÷ 1000 = 11.25 kW; the height and the storeys change nothing; hot water adds 4 × 0.2 = 0.8 kW. The demand is 12.05 kW. The calculator proposes the 12 kW model, because it accepts a pump up to 10% below the demand: the design day comes round a few times each winter, and for the rest of the season the pump would run at part load anyway. If the same customer insulates the walls with 10 cm, the house moves to 55 W/m², the demand drops to 9.05 kW and the 10 kW model is enough.
Underfloor heating, radiators or mixed: the flow temperature changes the model
Underfloor heating works with water at 30–35 °C on the flow. Classic radiators need 50–55 °C, and on very cold days even more. The difference shows straight away on the bill: the Chofu SCOP is 4.68 at 35 °C and 3.61 at 55 °C, so the same house uses almost 30% more electricity on radiators than on underfloor heating. That is why the calculator asks what heating system you have.
For radiators or a mixed system, the calculator only proposes models from the R290 range, which take the flow temperature up to 75 °C. The R32 range stops at 60 °C and remains the choice for underfloor heating or fan coils. If you have old steel or cast iron radiators, most of the time they can stay; at the free sizing check we verify whether their radiating surface is enough at 55 °C. More in the articles on a heat pump with your existing radiators and a heat pump with underfloor heating.
Domestic hot water: how much it adds to the power and what cylinder you need
Each person who uses hot water daily adds about 0.2 kW to the power needed. For a family of four, that means 0.8 kW on top of the heating demand. The figure looks small, but in a well insulated 100 m² house it is the difference between 5.5 and 6.3 kW, that is, between a pump that copes and one that is at its limit in January.
The cylinder matters as much as the power. A heat pump heats water more slowly than a gas boiler, so it needs a larger volume and a generous coil: in practice 200 l for two or three people and 300 l from four upwards. If you already have heating and want the pump only for radiators or underfloor heating, choose "Heating only" in the calculator and hot water is left out of the calculation. Which cylinder works, and why not just any will do, in the article on hot water cylinders.
What happens at −15 °C or −20 °C
The power printed on an air-to-water heat pump is measured at 7 °C outside and 35 °C on the flow. The lower the outdoor temperature, the lower the power delivered, while the house asks for more and more. That is why sizing is done for the design outdoor temperature of your county, from the climate zone table above: −15 °C in zone II (Oradea, Arad, Bucharest), −18 °C in zone III (Cluj, Sibiu, Iași), −12 °C on the coast.
Chofu heat pumps are guaranteed to run down to −20 °C, and the data sheet of each model shows the power at −7 °C, so you can see how much of the nominal figure is left when it is properly cold. The calculator here does not yet correct the W/m² value by zone; at the free sizing check we take that step, with the design temperature of your town and the heating system you already have. How the unit works when it is freezing outside, in short, in how an air-to-water heat pump works.
Why oversizing costs more than you think
The temptation is to take "a bigger one, just in case". A heat pump that is too large for the house cannot turn its power down far enough on ordinary winter days, at 0 or 5 °C, when the house may need a third of the design demand. It starts, reaches the temperature in a few minutes, stops, starts again. Every start means electricity used without useful heat and wear on the compressor. The calculator flags a model as oversized when its power exceeds the demand by more than 35%.
The most common mistake is copying the power of the gas boiler. A 24 or 28 kW wall-hung boiler was not chosen for the heat losses of the house but for instant hot water in the shower; the same house usually needs 8–12 kW from a heat pump. The 15 year calculation, with what you gain and what you lose, is in a heat pump instead of the gas boiler. Above 380 m² or above 16 kW, the calculator proposes two or three identical pumps in cascade, the solution for guesthouses and large houses, instead of a single industrial unit.
What your heating costs: gas, electricity, pellets or firewood
The "What your heating costs you per year" panel under the calculator compares the Chofu pump with the heating you have or are considering: condensing gas boiler, pellet boiler, firewood, direct electric heating and other brands of heat pump. You pick the electricity tariff you pay and see the cost per year and per month for the house described above. The method is written under the table too, so you can check it:
heat required = heating power × equivalent hours × gains factor; fuel = heat ÷ seasonal efficiency; cost = fuel × price of one kWh
The heating power is the demand without the hot water share. The equivalent hours are those of zone II, 1977 a year, worked out from Eurostat degree days for 2021–2025. The Chofu pump goes in with a SCOP of 4.68 on underfloor heating or 3.61 on radiators, the gas boiler with an efficiency of 0.92, the pellet boiler and firewood with 0.75, direct electric heating with 1.0. Energy prices are those at the date of publication, 1.35 lei/kWh for electricity on the average tariff and 0.28 lei/kWh for gas, and we update them when the market changes. Consumption over one winter, by model, with real bills, in what a winter with a heat pump costs; how the bill falls with solar panels in heat pumps and solar panels.
How we check the sizing, free of charge
The calculator result is a good estimate, not a quote. When you press "Send sizing", your answers reach us at NEDAVI together with the proposed model. A technician checks them, asks for anything missing (the house plan, photos of the heating system, year of construction, the energy performance certificate if there is one) and replies within one working day with the confirmed power and an itemised quote: pump, cylinder, installation, delivery. For houses with a mixed system, old radiators or more than 250 m², we also do a site survey before the quote. It commits you to nothing.
Frequently asked questions about heat pump sizing
How many kW per square metre does a heat pump need?
What heat pump power do I need for a 100 m² house?
What power do I need for 150 m²?
And for a 200 m² house?
How many square metres does a 6, 8, 10, 12 or 16 kW heat pump heat?
Can I use the power of the gas boiler I have?
Will a heat pump work with my existing radiators?
Do I need a backup electric heater?
Single phase or three phase?
Articles on sizing and power
- A heat pump for 100, 150 or 200 m²: how many kW you need, the complete guide with the table by insulation.
- 6 kW heat pump, 10 kW, 12 kW and 16 kW three phase: which house each model is for.
- Single phase or three phase: what supply the calculated power asks for.
- What a winter with a heat pump costs, consumption by model and by month.
- Does a heat pump work with old radiators? and a heat pump with underfloor heating.
- R290 or R32: why the refrigerant decides the flow temperature.
Would you rather talk to someone
Call us and we'll size it together
NEDAVI COM SRL · Str. Greierului nr. 28, 410286 Oradea, Bihor County · official Chofu importer for Eastern Europe.