Part of the NEDAVI family · official Chofu importer in Eastern Europe +40 757 026 503 office@pompacaldura.ro Monday – Friday, 9:00 – 17:00
Chofu Heat pumps by NEDAVI
Heat pump Chofu 12 kW: The outdoor unit

Line R32

Heat pump Chofu 12 kW

Product code AEYC-1242XU-CH

Refrigerant
R32
Output
12 kW
Power supply
230 V single-phase
Type
block

The 12 kW model covers a 180 to 220 square meter home. It works most effectively with underfloor heating or oversized radiators.

4,793 € 25,600.08 lei
incl. VAT
  • In stock at the warehouse in Oradea · delivery in 3–5 business days
  • Palletized transport throughout the countryor free pick up from Oradea
  • Return in 14 daysfrom the reception, without saying why
  • Warranty 3 years unit, 5 year compressorwith authorized commissioning and annual inspection
  • Payment by card or bank transfer
Request a full quote

The transportation of the ordered product is carried out exclusively through specialized companies, in a palletized manner in safe conditions and to reduce the risk of damage during transport.

The transportation of the ordered product is carried out exclusively by specialized companies, on pallets, in safe conditions and to reduce the risk of damage during transport.

  • 3-year warranty on the unit5-year compressor warranty
  • Works at −25 °Cwithout a backup heater
  • Spare parts in stockdelivered within 48 h nationwide
  • No F-gas certification neededmonobloc, no refrigerant connections on site

Heat pump Chofu 12 kW AEYC-1242XU-CH – R32

The Chofu AEYC-1242XU-CH heat pump is a monobloc air-to-water equipment, with a nominal power of 12 kW and DC Inverter technology. The model is intended for heating and cooling buildings, as well as for preparing domestic hot water by connecting to a compatible boiler.

The monobloc construction means that the refrigeration circuit is closed in the outdoor unit. The connection to the indoor installation is made hydraulically, without the need to build a refrigeration line between two units on site. The equipment uses refrigerant R32 and operates with a single-phase power supply at 230 V.

Performance and efficiency

According to the manufacturer's published data, the pump delivers 12 kW at conditions A7 and achieves a COP of W35 . The COP value shows that, under the respective test conditions, for every kilowatt of electrical energy used, approximately 4.3 kW of thermal energy is delivered.

The declared SCOP is 4.7 in low temperature applications and 3.2 in high temperature regime. For this reason, the model works most efficiently with underfloor heating, fan coils or radiators sized for low and medium temperatures.

The pump can deliver water at a temperature of up to 60 °C. At low outdoor temperatures, the available power is lower than the nominal value: at −7 °C and water at 35 °C, the indicated power is approximately 8.61 kW. This must be taken into account when sizing the installation.

What surface area can the 12 kW pump Chofu heat?

The heated surface cannot be determined solely by the power listed in the pump name. The result depends on the heat loss of the building, the climate zone, the area of windows, the height of the rooms and the required temperature in the installation.

For a home with very good thermal insulation – approximately 15–20 cm on the exterior walls, a properly insulated roof and high-performance windows – the following indicative values can be used:

  • underfloor heating: approximately 180–220 m² under normal conditions, with a maximum indicative limit of 220–230 m² in the case of a very energy-efficient building;
  • heating with radiators: approximately 120–150 m², with a maximum indicative limit of 150 m² , if the radiators are sized for low or medium temperatures.

The 220 m² floor area limit can only be considered in a building with very low heat loss. The 15–20 cm insulation thickness is important, but it is not enough on its own. The roof insulation, thermal bridges, joinery, building tightness and climatic zone must also be checked.

In a poorly insulated home or one equipped with small radiators that constantly require very hot water, the heated surface area will be smaller and energy consumption will increase.

Use with underfloor heating

Underfloor heating is the recommended application for achieving high efficiency. The large transfer surface allows operation with low water temperatures, which favors a better COP and stable operation. DC Inverter technology adapts the compressor power to the current building needs. The pump can operate in longer and more uniform cycles, reducing frequent starts and stops and maintaining a constant indoor temperature.

Use with radiators

The Chofu 12 kW pump can also be used with radiators, but these should be checked before installation. The best results are achieved with oversized radiators, capable of covering the heating demand at lower flow temperatures than those used by a conventional boiler.

If the existing system constantly requires water at 60 °C to heat the home, efficiency will be lower. In this situation, it may be necessary to enlarge the radiators, replace certain heating elements or improve the building's insulation.

Heating, cooling and domestic hot water

The pump can provide heating in the cold season and cooling in the summer, if the indoor installation is designed for both regimes. For cooling, fan coils or other compatible terminals are recommended, together with appropriate insulation of the pipes to prevent condensation.

Domestic hot water preparation requires a separate boiler, with a coil sized for heat pump operation. The volume of the boiler is chosen based on the number of users and daily consumption.

Correct system sizing

The Chofu AEYC-1242XU-CH heat pump is suitable for well-insulated homes with a medium to high heat demand. To achieve low consumption and stable operation, the choice of model should be made based on a calculation of heat losses, not exclusively based on the building surface area.

Before purchasing, check the available power at the calculated outdoor temperature, the required flow temperature, the electrical installation, the water flow rate and the total volume of the circuit. Correct sizing contributes to constant comfort, good efficiency and long-term compressor protection.

At a glance

Heat pump Chofu 12 kW , in short

Third model single-phase as power from line R32: 12 kW at 230 V, with refrigerant R32 (fluorinated). It raises the water temperature to 60 °C and works most efficiently with underfloor heating or oversized radiators. The site's sizing calculation gives it about 146–220 m², with 10 cm of insulation on the walls and 20 cm in the attic. From the data sheet: COP 4.3 at A7/W35, SCOP 4.7 with floor (35 °C) and 3.2 with radiators (55 °C) and 8 kW at −7 °C outside.

Compared to Heat pump Chofu 10 kW, the smaller model in the line: 2 kW more, € 726 more expensive, Lower COP (compared to 4.39), 29 kg heavier and larger casing. Compared to Heat pump Chofu 16 kW, the next model in power: 4 kW less, € 218 cheaper, 18 kg lighter and the same case.

Same power and supply, on another line: Heat pump Chofu 12 kW Standard, with R290 (propane) and flow up to 75 °C, price € 56 higher.

Technical data

Technical data Chofu 12 kW ( AEYC-1242XU-CH )

Chofu AEYC-1242XU-CH . The values are those in the technical data sheet, measured according to EN 14511.

Performance

Efficiency class at 35 °C
A+++
Efficiency class at 55 °C
A++
COP
4.30 (A7/W35)
SCOP
4.7 at 35 °C, 3.2 at 55 °C
Heating output
12.0 kW thermal
Output at −7 °C
8.61 kW (−7 °C, W35 , part load), COP 2.64
Power input
2.79 kW (A7/W35)
Minimum operating temperature
−25 °C outside
Maximum flow temperature
60 °C

Electrical

Power supply
230 V / 50 Hz
Current draw
12.2A (max. 23.0A)
Operating noise
62 dB(A) sound power, 51 dB(A) sound pressure

Construction

Refrigerant
R32, GWP 675
Refrigerant charge
2.20 kg
Compressor
Panasonic DC twin rotary
Circulation pump
Panasonic, built in
Water-side heat exchanger
Stainless steel
Air-side heat exchanger
Copper
Casing
Galvanised steel sheet, electrostatically painted
Controls
External controller with thermostat
Flow / return connection
1 inch, DN20
Dimensions (H × W × D)
1,418 × 1,000 × 330 mm
Weight
98 kg (111 kg gross)

Warranty and delivery

Unit warranty
3 years
Compressor warranty
5 years
After-warranty service
Parts within 48 h, nationwide
Availability
In stock in Oradea, delivered in 3–5 days

House

m²
m

Heating system

What do you want from the pump?

Heating type
People
m

Insulation

Wall insulation
cm
Loft insulation
cm
Windows

question

Before you buy

Any other questions? Call us at +40 757 026 503 or write to us.

What surface area does the 12 kW pump heat?
Third model single-phase as power from line R32 heats about 146–220 m² in a house with 10 cm of insulation on the walls and 20 cm in the attic. For your home, fill out the calculator on the page.
How much does it cost and what is included in the price?
Third model single-phase as power from line R32 costs € 4,793 with VAT ( 25,600.08 lei at today's NBR exchange rate), just the pump. You choose the transportation upon payment, and the installation is done by a partner installer Chofu , through the complete offer.
When does it arrive and how much does shipping cost?
From stock in 3–5 business days; shipping costs 450 lei including VAT.
What warranty does it have?
3 years for the unit, 5 for the compressor, plus 2 years legal warranty. Warranty conditions
Who does the installation?
A partner installer Chofu , chosen by you; NEDAVI delivers the equipment.

Offers

What else you get with the heat pump.

Current NEDAVI offers. They come on top of the catalogue price; they don't replace it.

Free

Controller included

You get the controller with thermostat free with any heat pump in the range.

Request a quote

−2%

With two heat pumps

When you order two Chofu heat pumps, you take 2% off the final price.

Request a quote

−3%

Heat pump plus solar

Buy a heat pump and get 3% off a Westech evacuated-tube solar system.

Request a quote

Pompa de caldura aer apa Chofu Silviu Oprișan · NEDAVI SOLAR

Only loads from YouTube when you press play. Open on YouTube

How it works

Why it puts out more heat than the electricity it uses.

COP 4.30 (A7/W35)
Electricity paid for 1 kW
Heat delivered 4.30 kW

Third model single-phase as power from line R32 · Output at −7 °C: 8.61 kW (−7 °C, W35 , part load), COP 2.64

Similar models

Other outputs in the same range

Heat pump Chofu 12 kW
4,793 € · 25,600.08 lei, incl. VAT
Request a full quote

News and offers Chofu , by email

Up to one email per month with new designs, offers and heating tips. You can unsubscribe at any time.