Free
Controller included
You get the controller with thermostat free with any heat pump in the range.
Line R32
Product code AEYC-1242XU-CH
The 12 kW model covers a 180 to 220 square meter home. It works most effectively with underfloor heating or oversized radiators.
The transportation of the ordered product is carried out exclusively through specialized companies, in a palletized manner in safe conditions and to reduce the risk of damage during transport.
The transportation of the ordered product is carried out exclusively by specialized companies, on pallets, in safe conditions and to reduce the risk of damage during transport.
The Chofu AEYC-1242XU-CH heat pump is a monobloc air-to-water equipment, with a nominal power of 12 kW and DC Inverter technology. The model is intended for heating and cooling buildings, as well as for preparing domestic hot water by connecting to a compatible boiler.
The monobloc construction means that the refrigeration circuit is closed in the outdoor unit. The connection to the indoor installation is made hydraulically, without the need to build a refrigeration line between two units on site. The equipment uses refrigerant R32 and operates with a single-phase power supply at 230 V.
According to the manufacturer's published data, the pump delivers 12 kW at conditions A7 and achieves a COP of W35 . The COP value shows that, under the respective test conditions, for every kilowatt of electrical energy used, approximately 4.3 kW of thermal energy is delivered.
The declared SCOP is 4.7 in low temperature applications and 3.2 in high temperature regime. For this reason, the model works most efficiently with underfloor heating, fan coils or radiators sized for low and medium temperatures.
The pump can deliver water at a temperature of up to 60 °C. At low outdoor temperatures, the available power is lower than the nominal value: at −7 °C and water at 35 °C, the indicated power is approximately 8.61 kW. This must be taken into account when sizing the installation.
The heated surface cannot be determined solely by the power listed in the pump name. The result depends on the heat loss of the building, the climate zone, the area of windows, the height of the rooms and the required temperature in the installation.
For a home with very good thermal insulation – approximately 15–20 cm on the exterior walls, a properly insulated roof and high-performance windows – the following indicative values can be used:
The 220 m² floor area limit can only be considered in a building with very low heat loss. The 15–20 cm insulation thickness is important, but it is not enough on its own. The roof insulation, thermal bridges, joinery, building tightness and climatic zone must also be checked.
In a poorly insulated home or one equipped with small radiators that constantly require very hot water, the heated surface area will be smaller and energy consumption will increase.
Underfloor heating is the recommended application for achieving high efficiency. The large transfer surface allows operation with low water temperatures, which favors a better COP and stable operation. DC Inverter technology adapts the compressor power to the current building needs. The pump can operate in longer and more uniform cycles, reducing frequent starts and stops and maintaining a constant indoor temperature.
The Chofu 12 kW pump can also be used with radiators, but these should be checked before installation. The best results are achieved with oversized radiators, capable of covering the heating demand at lower flow temperatures than those used by a conventional boiler.
If the existing system constantly requires water at 60 °C to heat the home, efficiency will be lower. In this situation, it may be necessary to enlarge the radiators, replace certain heating elements or improve the building's insulation.
The pump can provide heating in the cold season and cooling in the summer, if the indoor installation is designed for both regimes. For cooling, fan coils or other compatible terminals are recommended, together with appropriate insulation of the pipes to prevent condensation.
Domestic hot water preparation requires a separate boiler, with a coil sized for heat pump operation. The volume of the boiler is chosen based on the number of users and daily consumption.
The Chofu AEYC-1242XU-CH heat pump is suitable for well-insulated homes with a medium to high heat demand. To achieve low consumption and stable operation, the choice of model should be made based on a calculation of heat losses, not exclusively based on the building surface area.
Before purchasing, check the available power at the calculated outdoor temperature, the required flow temperature, the electrical installation, the water flow rate and the total volume of the circuit. Correct sizing contributes to constant comfort, good efficiency and long-term compressor protection.
At a glance
Third model single-phase as power from line R32: 12 kW at 230 V, with refrigerant R32 (fluorinated). It raises the water temperature to 60 °C and works most efficiently with underfloor heating or oversized radiators. The site's sizing calculation gives it about 146–220 m², with 10 cm of insulation on the walls and 20 cm in the attic. From the data sheet: COP 4.3 at A7/W35, SCOP 4.7 with floor (35 °C) and 3.2 with radiators (55 °C) and 8 kW at −7 °C outside.
Compared to Heat pump Chofu 10 kW, the smaller model in the line: 2 kW more, € 726 more expensive, Lower COP (compared to 4.39), 29 kg heavier and larger casing. Compared to Heat pump Chofu 16 kW, the next model in power: 4 kW less, € 218 cheaper, 18 kg lighter and the same case.
Same power and supply, on another line: Heat pump Chofu 12 kW Standard, with R290 (propane) and flow up to 75 °C, price € 56 higher.
Technical data
Chofu AEYC-1242XU-CH . The values are those in the technical data sheet, measured according to EN 14511.
House
Heating system
Insulation
What's included besides the heat pump
The “from” amount only covers items that already have a price; we set the rest in the quote. This is an estimate, not a final price. Installation and delivery are not included: an authorised Chofu partner installer does the installation, and we set the delivery in the quote, based on your address. Final price after survey and quote.
Request a full quoteRequest received
We'll send you the full quote, with the final price, within one working day. If needed, we'll call you first to arrange a survey.
For a 140 m² house, well insulated, 8.5 kW, underfloor heating.
What do you pay for electricity?
| System | Per year | Per month | Compared with Chofu |
|---|---|---|---|
| Wood-fired boiler | 3,781 lei | 315 lei | −617 lei |
| NIBE S2125-8 | 4,116 lei | 343 lei | −281 lei |
| Bosch Compress 3400i AWS | 4,361 lei | 363 lei | −37 lei |
| Chofu heat pump | 4,398 lei | 366 lei | – |
| Daikin Altherma 3 M, 8 kW | 4,465 lei | 372 lei | +67 lei |
| Condensing gas boiler | 4,640 lei | 387 lei | +242 lei |
| Panasonic Aquarea L, 9 kW | 4,775 lei | 398 lei | +378 lei |
| Pellet boiler | 9,574 lei | 798 lei | +5,177 lei |
| Direct electric heating | 20,582 lei | 1,715 lei | +16,184 lei |
| IDM AERO SLM | SCOP not published at 35 and 55 °C | ||
Offers
Current NEDAVI offers. They come on top of the catalogue price; they don't replace it.
Free
You get the controller with thermostat free with any heat pump in the range.
−2%
When you order two Chofu heat pumps, you take 2% off the final price.
−3%
Buy a heat pump and get 3% off a Westech evacuated-tube solar system.
Only loads from YouTube when you press play. Open on YouTube
How it works
Third model single-phase as power from line R32 · Output at −7 °C: 8.61 kW (−7 °C, W35 , part load), COP 2.64
Similar models
Up to one email per month with new designs, offers and heating tips. You can unsubscribe at any time.
Powered by Life Value
Cookies on this site
We only use the cookies the site cannot work without. With your consent, we also count visits, through Google Analytics, to see which pages are useful. You can change your choice at any time; the details are in our cookie policy.